Galaxy Flex Installer Manual
Program Zones [52]
111
Scroll through the available channels, and then press
ent
to select the available audio
channel.
14=Fire Confirm
Use this attribute to enable this zone to be used as a fire confirm. A Fire zone with this
attribute enabled must be activated first.
15=Camera
Use this attribute to link the zone to a camera. When an alarm activation occurs, the camera
will record an image sequence for alarm verification.
Batch learn [52.3]
Use this option to learn a series of wireless detectors onto the system in a single operation.
Devices are added sequentially from the selected zone address.
1.
Select a start zone address and press
ent
.
2.
Insert the battery in the first detector and activate the tamper switch. The serial number
of the detector is recorded and displayed for 2 seconds. The panel provides a
confirming beep when each wireless detector is successfully learned.
If the signal strength is less than 3/10, the message
Signal strength too low
is
displayed for 2 seconds.
3.
Repeat step 2 on all the remaining wireless detectors in turn.
Camera Zones [52.4]
Use this option to view only the zones that belong to camera PIRs
Zone Function menu
01 = Final
15 = PA Delay
32 = Set Log
02 = Exit
16 = PA Delay Silent
33 = Custom-A
03 = Intruder
18 = Spare
34 = Custom-B
05 = Security
19 = Fire
39 = Keyswitch Reset
07 = Entry
20 = Tamper
40 = Bell Fail
08 = Push Set
22 = Beam Pair
41 = Intr Low
09 = Keyswitch
23 = Battery Low
42 = Intr High
10 = Secure Final
24 = Line Fail
43 = PSU Fault
11 = Part Final
25 = AC Fail
44 = Fault
12 = Part Entry
26 = Log
45 = Entry 2
13 = PA
28 = Video
53 = Monitor
14 = PA Silent
29 = Video Exit