
Galaxy Flex Installer Manual
Additional programming
29
Additional programming
Use this section as a quick reference to some of the functions you may wish to program or
modify.
Parameters (51 ent)
Entry Time (
05 ent
) – defines the user unsetting time
Exit Time (
04 ent
) – defines user exit time before system set
Bell Time (
01 ent
) – bell sounding time (default = 15 mins)
Bell Delay (
02 ent
) – delay bell activation for up to 20 mins
Reset Levels (
65 ent
) – defines which user type can reset specific faults
Confirm (
55 ent
) – controls how confirmed alarms are generated
Keypad Access (
54 ent
) – disable unset on entry
RF Parameters (
60 ent
) – access these options:
RF Address (
1 ent
) – enable and disable wireless virtual RIO addresses
RF Fob PA (
2 ent
) – enable to allow users to program the Panic Alert function of
wireless keyfobs
Program zones (52 ent + Zone Address)
Function (
01 ent
) – assign zone function
Descriptor (
02 ent
) – name a zone (up to 16 characters)
Part (
05 ent
) – zone included in a part or night setting option
Omit (
04 ent
) – zone omitted when using an omit function
Chime (
03 ent
) – opened zones cause momentary chime when system unset
Group (
10 ent
) – assign zone to a group, if enabled
Resistance Select (
09 ent
) – change pre-defined resistance for the selected zone
Activity Monitor (
08 ent
) – check zone activity
RF Options (
11 ent
) – access these options:
Serial No. (
1 ent
) – manual or self-learn entry of wireless device serial number
Loop No. (
2 ent
) – loop number of multiple input wireless devices
Supervision (
3 ent
) – enable for periodic device supervision
Auto Reset (
4 ent
) – enable to force zone to automatically close after five seconds
Signal Level (
5 ent
) – display device signal level