Appendix G: Peripherals
Galaxy Flex Installer Manual
240
4.
Close the door. LED 2 switches off and LED 3 switches on. The door must be closed
within the programmed Close Timeout. If the door remains open longer than this, an
alarm is activated.
Card-Held function
The MAX
4
or DCM card can be assigned a single menu option (refer to the
MAX Function
[42.1.8]
menu option). To activate the function assigned to the MAX
4
or DCM card, hold
the card in front of the reader for three seconds; all of the LEDs switch on. If a keypad has
been assigned to the MAX function then it displays the details of this option. If no keypad is
assigned, pressing a key on any of the keypads assigned to a common group displays the
card-held function.
Card-Held system setting
If the MAX
4
or DCM card is assigned one of the setting options (options 12, 13, and 16 to
19), the card-held functions starts the setting procedure for the groups assigned to the card.
Note:
If Group Restriction is assigned, only the groups that are common to both the MAX
4
reader and the MAX
4
user are set/unset.
To unset the system using the MAX
4
or DCM card, swipe the reader with a valid card. The
reader beeps. All of the groups assigned to the card are instantly unset.
MAX
4
Log
Refer to Access Doors [25]
MAX
4
events print out
Refer to
Online Print [51.28]
, and
Online Level [51.29]
.
Downloading the MAX
4
/ DCM Log
The MAX
4
/DCM event log can be downloaded to Remote Servicing by using the
MAX/DCM Log copy option in Remote Servicing.