![Honeywell Galaxy Flex 100 V3 Installer Manual Download Page 203](http://html.mh-extra.com/html/honeywell/galaxy-flex-100-v3/galaxy-flex-100-v3_installer-manual_153326203.webp)
Galaxy Flex Installer Manual
Appendix B: SIA & contact ID event codes
203
Ev
SIA Event
Log
Log Event
Ev Type Trigger
Contact
Description
Event
Description
ID Event
H - Holdup
HA
Holdup Alarm
PA PA
Silent zone alarm
ZONE
1.PA/DURE
122
PA DEL/SL+
PA Delay Sil.zone alarm
ZONE
1.PA/DURE
122
DURESS
Duress with code
USER
1.PA/DURE
121
PA UNSET+
PA Unset zone alarm
ZONE
1.PA/DURE
122
HB
Holdup Bypass
OMITTED
Holdup zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
HJ
Hold Troub rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
HR
Hold Restoral
PA SILENT-
PA Silent zone restored
ZONE
1.PA/DURE
122
18.ZN RESTO
PA DEL/SL-
PA Delay Sil.zone rest.
ZONE
1.PA/DURE
122
18.ZN RESTO
PA UNSET-
PA Unset zone restored
ZONE
1.PA/DURE
122
18.ZN RESTO
HT
Holdup Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
HU
Hold Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573
I - Peripheral Fault
IA
Equipment Fail
FAULT+
Specific condition reported
ZONE
20.FAULT
330
IR
Equipment Fail Rest FAULT-
Condition restored to normal
ZONE
20.FAULT
330
IV
Picture Ready
PIC READY
Picture(s) ready to send
MOD.
ALWAYS TR
None
J - Wrong code, Time changed
JA
Code Tamper
WRONG CD
Wrong code alarm act.
MOD.
9.TAMPER
461
Invalid Code
INVALID CD
Invalid Code entered
MOD.
ALWAYS TR
None
JL
LOG 90%
MISC
ALWAYS TR
632
JR
TIMER A
MISC
NONE
0
TIMER B
MISC
NONE
0
AUTOTIMER
MISC
NONE
0
LOCKTIMER
MISC
NONE
0
JT
Time changed
NEW T/D
Time/Date modified
USER
ALWAYS TR3 625
K - Heat (Custom SIA - See Note 2)
KA
Alarm
Note 1
zone in alarm
ZONE
5.CUS ZON
Note 1
KB
Bypass
OMITTED
zone omitted
ZONE
8.OMIT
573
F
Force omit after rearm
ZONE
8.OMIT
573
KJ
Trouble Rest
LOW RES-
Restor zone resistance
ZONE
15.TROUBL
380
HIGH RES-
Restor zone resistance
ZONE
15.TROUBL
380
KR
Alarm Restore
Note 1
zone restored
ZONE
5.CUS ZON
Note 1
18.ZN RESTO
KT
Trouble
LOW RES+
Low resistance on zone
ZONE
15.TROUBL
380
HIGH RES+
High resistance on zone
ZONE
15.TROUBL
380
KU
Unbypass
FORCE OMT-
Unomitted after rearm
ZONE
8.OMIT
573
L - Phone, Program
LB
Program begin
E
Engineer mode entered
MISC
ALWAYS TR
627
TEST O/P
USER
NONE
0
FULL TEST
SET
NONE
0
MOD T/D
USER
NONE
0
MOD CODES
USER
NONE
0
MOD REM
USER
NONE
0
OMIT ZONE
USER
NONE
0
ENG PARAM
USER
NONE
0
ENG ZONES
USER
NONE
0