Galaxy Flex Installer Manual
Program Zones [52]
107
Note:
Library words are a maximum of 12 characters and upper case only.
3=Chime
Enable the Chime attribute to make a zone chime momentarily whenever it is opened while
the system is unset. The Chime attribute defaults to 0 (disabled) for all zone functions.
Use
A
or
B
to toggle the status of the Chime attribute, and then press
ent
to accept the
programming.
Note:
This attribute only works when the
Chime [15]
option is enabled.
4=Omit
Enable the Omit attribute to allow these zone omit functions to be programmed,
11=OMIT
ZONES
,
46=GROUP OMIT
).
The Omit attribute defaults to 0 (disabled) for all zone functions.
Use
A
or
B
to toggle the status of the Omit attribute, and then press
ent
to accept the
programming.
5=Part
This option has two sub menus to define if the zone is included in the Part and Night set
modes.
1=Part Set
2=Night Set
Both are programmed in the same way.Disable the Part attribute to ensure the zone is
excluded from the setting procedure when either the part or night setting sub-options are
used to set the system:
13=PART SET
. The Part attribute defaults to 1 (enabled) for all
zone functions except zones programmed as
09=Keyswitch
.
Use
A
or
B
to toggle the status of the Part attribute, and then press
ent
to accept the
programming.
6=Resp. Time
This function is only applicable to zones on RIO rev 1.2 and Smart PSU rev 0.7 and above.
Use this option to select either Fast (10 ms), System (default value programmed in
Parameters [51]
, option 27) or Slow (750 ms), for each zone.