68
Cable Connector Configurations
Aux Port Configuration Cable*
PN 57-57008x-N-3
Pin
Function**
9-Pin D-Type Connector
1
No Connect
2
Output from Scanner
3
Input to Scanner
4
No Connect
5
Ground
6-9
No Connect
RS232 LSO/AUX Cable
PN 57-57099x-3 or PN 57-57099x-3-12
Pin
Function
†
10-Position Modular Plug
1
Signal Ground
2
RS232 from Aux / Secondary Scanner
3
RS232 to Aux / Secondary Scanner
4
RTS from Aux / Secondary Scanner
5
CTS to Aux / Secondary Scanner
6-8
No Connect
9
+ 5VDC – Transformer / Direct
10 Shield Ground
*
This configuration cable was designed to be used with the MS2420 auxiliary connector only.
**
All signals are referenced from the MS2420 scanner.
†
Specifications are subject to change without notice.
All signals are referenced from the auxiliary / secondary scanner.