8
Scale Capacities
Capacity: kg unit 15 kg
lb. unit 30.0 lb.
Minimum Increment: kg unit 0.005 kg
lb. unit 0.01 lb.
Maximum Static
Weight: kg unit 75 kg
lb. unit 150 lb.
Adjustments
required: Calibration is required for scaled units.
Electrical
Voltage Supply: 4A @ +5V / 0.8A @ +12V
Operating Power: 11.2 Watts
Standby Power: 4.0 Watts
Operating Current: 1.7A @ 5.2V / 0.2A @ 12V
Standby Current: 0.6 A @ 5.2V / 0.07A @ 12V
DC Transformers: Class I; 5.2VDC @ 4A; 12VDC @ 1.5A
For Regulatory Compliance Information, refer to pages 69 - 71.
Environmental
Operating
Temperature: 0°C to 40°C (32°F to 104°F)
IP Rating: IP 55
Light Levels: 4842 Lux (450 footcandles)
Storage
Temperature: -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% Relative Humidity, Non-Condensing
Contaminants: Sealed to resist airborne particulate contaminants.
Ventilation: None Required
Specifications are subject to change without notice.