IGSMHS Installation and Setup Guide
3-12
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY
OPTIONS
DESCRIPTION
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
8
Exit Prog. Mode?
Y/N_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the
Exiting Programming Mode
paragraph in this section.
9
Comm Path
Choice
(IP&GSM)_
IP&GSM
IP
GSM
Press the [space] key to scroll through the
communication path choices. Press [ENTER] to
select.
For maximum reliability, select IP&GSM, and
ensure the Internet is connected using the
Ethernet cable.
NOTE:
After going from a “GSM” only com
path choice to an “IP” only choice, Prompt 68:
“DHCP” will default to No.
10
Device Mode
(ECP)_
ECP
Zone
Trig.
4204
Emu
Two
4204s
Press the [space] key to scroll through the
modes of operation.
Press [ENTER] to select mode.
See
Table 3-2
for ECP mode programming.
Important Information Regarding Primary Account (Prompts 11-13)
Account information is provided by the central station administrator.
11
Primary City ID
(??)_
[01-99]
Enter the 2-digit primary city ID, 01-99
(decimal).
12
Primary CS ID
(??)
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
13
Primary Sub ID
(????)
[0001-
9999]
Enter the 4-digit subscriber account number,
0001-9999 (decimal).
14
Device Address
(12)_
[01-15]
The IGSMHS communicates with the control
panel as a 4204 relay module. Enter the
appropriate address. For VISTA-10P, and
FA130CP Series control panels, this must be
address 12. For other controls, see the control
panel’s Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to
01-15. If using 2-4204 mode, the IGSMHS
assigns the second 4204 to the next higher
device address (e.g., if entering address 12
for the first 4204, then address 13 is
automatically assigned to the second 4204
module). Program the control panel
accordingly.
2. The device address(es) must be unique from
the "Keypad Address" entered in Prompt 16
and any other address used on the control
panel.
Summary of Contents for AlarmNet IGSMHS
Page 2: ......
Page 10: ...IGSMHS Installation and Setup Guide 1 6 ...
Page 18: ......
Page 40: ...IGSMHS Installation and Setup Guide 3 22 ...
Page 44: ...IGSMHS Installation and Setup Guide 4 4 ...
Page 52: ...IGSMHS Installation and Setup Guide A 2 ...
Page 54: ...IGSMHS Installation and Setup Guide B 2 ...
Page 58: ...IGSMHS Installation and Setup Guide D 2 ...
Page 59: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...NOTES ...
Page 62: ...NOTES ...