7810iR Internet Communication Module Installation and Setup Guide
6-10
Status Channel = 6 (Status Message)
NOTE:
Each channel that displays these message types corresponds to a particular type of
event. Because there are eight channels, it is possible for multiple events to be reported in
multiple channels in only one message.
(Example: The message “cccc 1555 5155 6”
would indicate an AC loss
and
a Telco Fault.)
Message Definition
Applies
to
Key Indicator:
Account # = “0000” or “0001”
0000 5555 1555 6
Central Station Communications Failure
(Note, this may be received via the (800) Backup
provision for an AlarmNet-A receiver, or by the secondary
C/S transceiver for AlarmNet-M
A&M
0000 5555 3555 6
Central Station Communications Failure Restore
A&M
0000 5515 5555 6
Central Station Radio Poll Timeout
A&I
0000 5535 5555 6
Central Station Radio Poll Timeout Restore
A&I
0000 5551 5555 6
Central Station Power-on Reset
A&M
cccc 1555 5555 6
AC Power Loss
A/M/C
cccc 3555 5555 6
AC Power Loss Restore
A/M/C
cccc 6555 5555 6
AC Power Loss Previously Reported
A/M/C
cccc 5155 5555 6
Low Battery
Note: This message indicates that the
radio’s
battery is
low, not that of the alarm control panel.
A/M/C
cccc 5355 5555 6
Low Battery Restore
A/M/C
cccc 5655 5555 6
Low Battery Previously Reported
A/M/C
cccc 5515 5555 6
Two-Way Radio Poll Timeout
A&I
cccc 5551 5555 6
Power-on Reset
A/M/C
cccc 5555 1555 6
Communications Failure
A/M/C
cccc 5555 3555 6
Communications Failure Restore
A/M/C
cccc 5555 6555 6
Communications Failure Previously Reported
A/M/C
Communications Failure Reminders
A&I
cccc 5555 5155 6
Telco Line Fault
A/M/C
cccc 5555 5355 6
Telco Line Fault Restore
A/M/C
cccc 5555 5655 6
Telco Line Fault Previously Reported
A/M/C
cccc 5555 5515 6
System Supervisory Fault
7720ULF
cccc 5555 5535 6
System Supervisory Fault Restore
7720ULF
cccc 5555 5565 6
System Supervisory Fault Previously Reported
7720ULF
cccc 5555 5551 6
Walk Test
7720ULF
cccc 5555 5553 6
Walk Test Exit
7720ULF
cccc 5353 5555 6
Exiting Battery Charge Mode
7720V2
Summary of Contents for AlarmNet 7810iR
Page 2: ......
Page 6: ...7810iR Internet Communication Module Installation and Setup Guide 1 2 ...
Page 12: ...7810iR Internet Communication Module Installation and Setup Guide 2 6 ...
Page 16: ...7810iR Internet Communication Module Installation and Setup Guide 3 4 ...
Page 62: ...7810iR Internet Communication Module Installation and Setup Guide 7 10 ...