Before using the product for the first time,
please read the instructions for use below and
retain them for later reference. The original
instructions were written in the Hungarian language.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be
supervised at all times to ensure that they do not play with the appliance.
SETUP
Featuring a high-powered halogen bulb, this weather-resistant floodlight is
perfectly suited for illuminating buildings or yards depending on the
ambient light conditions. Thanks to its stand, the floodlight can be safely
used in positions that otherwise do not facilitate attachment. It is crucial,
however, that the bulb is always in a perfectly level position. Otherwise, its
lifetime can be significantly shortened. Ensure that the opened legs are
placed on level ground in a stable manner preventing the stand from tipping
over.
The luminary generates a great amount of heat during operation.
Therefore, it should only be used outdoors where the free flow of air around
the unit allows excess heat to radiate off. Do not locate near flammable
materials. Do not touch the unit during operation!
The assembled stand-mounted floodlight should be connected to power
outlets rated at least IPX4.
CLEANING & MAINTENANCE
In order to ensure optimum functioning, the luminary may require cleaning
at least once a month, depending on the manner of use and degree of
contamination.
1. Before attempting to clean the luminary, power it off by unplugging it
from the electric outlet.
2. Allow the luminary to cool (for at least 30 minutes).
3. Use a slightly moistened cloth to clean the luminary’s exterior. Do not
use any aggressive cleaners. Avoid getting water inside of and on the
electric components of the luminary.
REPLACING BULBS AND SHIELD
Remove the screw located at the top of the luminary after it has cooled
down and power has been removed. After folding down the front panel, the
bulb can be removed from its socket by pushing it sideways. Avoid touching
the replacement bulb with your bare fingers, or clean it with a soft cloth after
insertion, as this may leave oil residue which can shorten its lifetime. At the
same time check the integrity of the shield, and replace with a new one if it
is cracked or broken.
TROUBLESHOOTING
WARNINGS
• Confirm that the appliance has not been damaged in transit.
• Installation of the product should only be performed by a specialist, in
compliance with the safety regulations in force.
• Can only be connected to power outlets rated IPX4.
• Power off the luminary and wait until it has cooled down before
attempting to replace the bulb (at least 30 minutes).
• The luminary may only be used with the shield in place.
• Replace shield if broken!
1 m
Repla
SPECIFICATIONS
Luminary
Meaning of IP44: Protected from the entry of solid objects larger than
1 mm in size.
Protected from splashing water (from all directions).
The luminary works with light bulbs of the following energy rating: C, D, E
Operating humidity:
<93% RH
Operating temperature:
-20 – +40 °C
Outside dimensions of luminary: 185 x 145 x 125 mm
2
Maximum projection:
270 cm
Adjustable height:
0,95 – 2 m
Lamp
Energy class of bulb bundled with floodlight: C
One 400 W line bulb included
230 V AC / 50 Hz
Can be used with max. 1 x 500 W line bulb
bulb: quartz-halogen, type R7s, 118 mm x O10 mm
ce shield if broken!
Please maintain the required distance from the
illuminated surface (and should be 1,0 m)!
In the event that the power cable should become damaged, it
should only be replaced by the manufacturer, its service facility
or similarly qualified personnel.
Do not discard with communal waste. At the end of its life, dispose
of product at a facility specializing in the collection of electronic
waste. If you have any question or remark in connection with this,
contact the seller or local waste management organization. By
doing so, you will protect the environment as well as the health of
others and yourself.
Solution
Check that the mains voltage is
230VAC / 50Hz.
Check the condition of the line bulbs
Cause
The floodlight does
not illuminate
halogen floodlight