HLP-C
+
Inverters
VIII. Function List
Parameter and Function List (Part 1)
Function
code
Function
Set Range & Function
Explanation
Factory
Setting
C000 Main frequency
0.0~600.0Hz
0.00
C001 Accel. Time
0.1~6500S
5.0
C002 Decel. Time
0.1~6500S
5.0
C003
V/F Curve
0~16
00
C004 Max. voltage
0.1~255/510
220/380
C005 Base frequency
0.01~600
50/60
C006 Intermediate
voltage
0.1~255/510
*
C007 Intermediate
frequency
0.01~600
*
C008
Min. voltage
0.1~*
*
C009 Min. frequency
0.1~20.0Hz
*
C010 Max. frequency
10.0~600.0
50.00
C011 Frequency lower
limit
0.0~600
0.00
C012 Running control
0~2
0
C013 Running frequency
select
0~2
0
C014 Starting mode
select
0~1
0
C015 Stopping mode
0~1
0
C016
FOR/REV select
0~1
1
C017 STOP key select
0~1
1
C018
S-Curve Time
0~6500S
0
C019 Carrier frequency 0~15
09
C020 Starting Frequency 0.1~10
1.5
C021 Stopping
Frequency
0.1~10
1.5
C022 Jog Frequency
0~600
5.0
C023
Jog Accel/Decel
Time
0.1~25.0
1.0