Startup of the micro annular gear pump with the S-ND control unit
speed regulation
serial interface of PC
external voltage supply
24 V DC / 3 A
Status LED
S
D
mzr-pump
+
-
switch S1
figure 21
Connection of the micro annular gear pump mzr-4622 and the S-ND control unit
1.
Connect the motor cable to the 10-pole connector of the S-ND control unit.
The pin configuration is indicated in table 3.
2.
Connect the RS-232 port of the MCBL3006 with a free serial interface of a
PC. For this purpose use the delivered 9-pole null-modem cable.
3.
Put the potentiometer of the S-ND control unit to zero position by turning it
clockwise to the limit stop.
4.
Connect the voltage supply 24 VDC. This can be done with the integrated
DIN connector or, alternatively the 2-pole screw clamp (24 V = »+«;
GND = »-«). Pay attention to the correct polarity.
5.
You may now install the delivered software as described in the chapter 8
or 9.
While connecting the DC voltage pay attention to the correct polarity,
otherwise electronics may be damaged.