9 »Motion Manager« software (optional)
Operation manual mzr-4622
60
Technical data subject to change without prior notice!
Last update: March 2019
I25
;Load Velosity Integral Term
PP162
;Load Position Proportonal Term
PD5
;Load Position D-Term
CI16
;Load Current Intergral term
SP6000
;Load maximum Speed
MV0
;Minimum Velocity [rpm]
MAV25
;Minimum Analog Voltage [mV]
LL600000000
;Load Position Range Limits
LL-600000000
;Load Position Range Limits
LPN10
;Load Puls Number
STW1
;Load Step Width
STN32
;Load Step Number
ENCRES128
;Load Encoder Resolution
DEV50
;Load Deviation
DCE200
;Delayed Current Error
CORRIDOR10
;Load Corridor
SIN0
;Sinus Commutation deactived
SETPLC
;Set PLC-Inputs
EN
;Enable Drive
DIPROG
;Disable Program
COMPATIBLE0
;Deactived Compatible Mode
SR18
;Load Sample rate
NET0
;Set Network Mode
NE0
;Notify Error
ANSW1
;Answer Mode
NODEADR0
;Define Node Address
V0
;Select Velocity Mode
;--------------------------------------------------------------------------------------------------------------
;
Programm
;--------------------------------------------------------------------------------------------------------------
PROGSEQ
;write and save an empty program sequence (clear program memory)
END
Listing 1
file mzr-4622.mcl