HV100 Series High Performance Current Vector Inverter
16
DC power
supply
+24V
+24V is the circuit common power supply of
digital signal input terminal
Maximum output current 200mA
+10V
+10V is the circuit common power supply of
analog input and output terminals
Maximum output current 20mA
OP
The factory default is OP connected to +24V.
When using external signals to drive DI1
~
DI6,
OP needs to be connected to the external
power supply and disconnected from the +24V
power supply terminal
External power input terminal
COM
Digital signal and +24V power supply reference
ground
Internally isolated from GND
GND
Analog signal and +10V power supply reference
ground
Isolated internally from COM
Communic
ation
interface
485+
RS485+
Standard RS485 communication
interface is not isolated from GND.
Please use twisted pair or shielded
wire.
485-
RS485-
4.2.3 Jumper settings of main control board
JP2
OFF
Represents 485 communication terminal resistance
is not connected
ON
Represents 485 communication terminal resistance
is connected
JP3
Cin
Represents AI1 input current signal, 4-20mA
Vin
Represents AI1 input voltage signal, 0-10V
JP4
Vo1
Represents AO1 output voltage signal, 0-10V
Co1
Represents AO1 output current signal, 4-20mA
JP5
Vo2(Reserved)
Represents AO2 output voltage signal, 0-10V
Co2(Reserved)
Represents AO2 output current signal, 4-20mA
4.3 Basic wiring diagram
Inverter wiring is divided into main circuit and control circuit. The user can lift the cover of the shell, and the main circuit
terminal and the control circuit terminal can be seen at this time. The user must connect accurately according to the
following wiring circuits.