HV100 Series High Performance Current Vector Inverter
125
016 Group- Photovoltaic water pump parameters
16.00
Lack of water detect time
0
~
250s
10
16.01
MPPT low point operating voltage
0
~
MPPT High point operating voltage
350/200V
16.02
MPPT high point operating voltage
【
16.01
】~
1000/
【
16.01
】~
500
537/311V
16.03
Photovoltaic pump water shortage detection current corresponds to the ratio of no-load current
80.0
~
300.0%*No load current of motor
150.0
16.04
Minimum operating frequency of photovoltaic pump effluent
0.00Hz
~
~ upper limit frequency
20.00
If the bus voltage (d-12) is higher than the set value of MPPT high working voltage (16.02), run at the maximum
frequency; If it is lower than the set value of MPPT high-point working voltage (16.01), it will run at the frequency obtained
by (bus voltage /MPPT high-point working voltage) * maximum frequency; if the bus voltage reaches MPPT low-point
working voltage (16.01), it will run at the lowest running frequency (16.04); if the inverter runs above the lowest running
frequency, and the output current is less than the no-load current of motor * water shortage detection current of
photovoltaic pump.