4
Environmental Conditions
Warning
Store and use the motionCAT series products only under the following environmental conditions.
⚫
Ambient operating temperature: 0 to +50
C
⚫
Ambient operating humidity:
20 to 85% RH (without dew condensation)
⚫
Ambient storage temperature: -15 to +75
C
⚫
Ambient storage humidity:
10 to 90% RH (without dew condensation)
⚫
Atmosphere:
No corrosive gas, inflammable gas, oil mist, or dust
⚫
Altitude:
3,000m above sea level max. (Lower upper level of
temperature ranges by 2
C for every 300m.)
Compatible Cables and Communication System
Warning
Do not connect a communication cable to any product incompatible with Motionnet.
Use shielded LAN cables, CAT5e or above as communication cables.
The use of a cable other than these may cause an operating error.
The cable length between slaves or between the master and slave must be 60 centimeters
or more.
A too short cable may cause an operating error. The total transmission distance must be
within 50 meters. A too long transmission distance may cause an operating error.
Limit the number of modules per line to 32 or less. Connecting more than 33 modules may
cause an operating error.
Do not use duplicate module IDs (addresses) for modules on the same line.
Duplicate IDs may cause an operating error or a failure.
Summary of Contents for motionCAT HCPCI-MNT720M
Page 3: ......
Page 12: ...1 Warnings and Precautions...
Page 20: ...9 1 motionCAT Installation...
Page 109: ...98 4 Installation Guide...
Page 118: ...107 5 Device Driver Installation...
Page 122: ...111 6 Trial Operation...
Page 145: ...134 7 Accessories...
Page 147: ...136 8 Glossary...
Page 161: ...150 9 Connections to Drivers Supplied by Manufacturers...