MAINTENANCE
7-15
D. Hydraulic System
Parts
Quantity
Interval (Hours)
Page
8
50
100 250 500 1000 2000
1.
Check Hydraulic Oil Level
1
7-38
2.
Drain Hydraulic Oil Tank Sump
1
7-39
3. Change Hydraulic Oil
ZX17U-5A
26 L
(6.9 US gal)
7-40
ZX26U-5A
39 L
(10.3 US gal)
4.
Clean Suction Filter
1
Each time when hydraulic oil is changed
7-40
5.
Replace Full-Flow (Return)
Filter Element
Filter-Paper Element
1
7-44
High Performance
Element (Optional)
1
6. Replace Pilot Oil Filter Element
1
7-46
7. Check Hoses and Lines
for leaks, loose
-
7-48
for cracks, bend, etc.
-
7-48
:
Changing interval differs according to the brand of hydraulic oil used, kind of filter element or average
attachment operating availability.
Refer to the "Change Hydraulic Oil" and "Replace Full-Flow Filter Element".
: Maintenance required only during first time.
E. Fuel System
Parts
Quantity
Interval (Hours)
Page
8
50
100 250 500 1000 2000
1.
Check Fuel Level
1
7-55
2.
Check Water Separator
1
7-56
3. Drain Fuel Tank Sump
1
As required
7-57
4.
Replace Fuel Filter Element
1
7-58
5.
Check Fuel Hoses
for leaks, cracks
-
7-59
for cracks, bend, etc.
-
7-59
F. Air Cleaner
Parts
Quantity
Interval (Hours)
Page
8
50
100 250 500 1000 2000
1.
Air Cleaner Element
Clean
1
7-60
Replace
1
After cleaning 6 times or 1 year
7-60
:
Shorten the interval in a dusty work site.
Summary of Contents for Zaxis 17U-5A
Page 4: ......
Page 8: ...CONTENTS MEMO ...
Page 12: ...MACHINE NUMBERS 4 MEMO ...
Page 84: ...OPERATOR S STATION 1 18 MEMO ...
Page 86: ...BREAK IN 2 2 MEMO ...
Page 108: ...DRIVING THE MACHINE 4 14 MEMO ...
Page 228: ...MAINTENANCE 7 88 MEMO ...
Page 230: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 232: ...STORAGE 10 2 MEMO ...
Page 240: ...TROUBLESHOOTING 11 8 MEMO ...
Page 250: ...SPECIFICATIONS 12 10 MEMO ...
Page 270: ...13 20 NUMERIC KEYPAD LOCK OPTIONAL ATTACHMENT MEMO ...
Page 274: ...INDEX 14 4 MEMO ...
Page 276: ......
Page 277: ......
Page 278: ......