![Hitachi Zaxis 17U-5A Operator'S Manual Download Page 189](http://html.mh-extra.com/html/hitachi/zaxis-17u-5a/zaxis-17u-5a_operators-manual_21508189.webp)
MAINTENANCE
7-49
9
10
8
7
6
4
5
12
13
12
13
11
Interval
(Hours)
Check Points
Abnormalities
Remedies
Every 250
hours
Hose covers
Leak (4)
Replace
Hose ends
Leak (5)
Replace
Hose covers
Exposed reinforcement (6)
Replace
Hose covers
Crack or blister (7)
Replace
Hose
Bend (8), Collapse (9)
Replace
Hose ends and
Fittings
Deformation or corrosion (10)
Replace
Lines
Interval
(Hours)
Check Points
Abnormalities
Remedies
Daily
Contact surfaces
of flange joints
Leak (11)
Replace
Bolts
Loose or leak (11)
Retighten or
replace O-ring
Welded surfaces
on flange joints
Leak (12)
Replace
Every 250
hours
Flange joint neck
Crack (13)
Replace
Welded surfaces
on flange joints
Crack (12)
Replace
Clamps
Missing or deformation Loose bolts
Replace or
retighten
Oil Cooler
Interval
(Hours)
Check Points
Abnormalities
Remedies
Every 250
hours
Hose ends and
Fittings
Leak (14)
Retighten or
replace
Oil Cooler
Leak (15)
Replace
M115-07-146
M115-07-147
M115-07-148
M115-07-149
M137-07-001
M137-07-007
15
14
MADB-07-021
Summary of Contents for Zaxis 17U-5A
Page 4: ......
Page 8: ...CONTENTS MEMO ...
Page 12: ...MACHINE NUMBERS 4 MEMO ...
Page 84: ...OPERATOR S STATION 1 18 MEMO ...
Page 86: ...BREAK IN 2 2 MEMO ...
Page 108: ...DRIVING THE MACHINE 4 14 MEMO ...
Page 228: ...MAINTENANCE 7 88 MEMO ...
Page 230: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 232: ...STORAGE 10 2 MEMO ...
Page 240: ...TROUBLESHOOTING 11 8 MEMO ...
Page 250: ...SPECIFICATIONS 12 10 MEMO ...
Page 270: ...13 20 NUMERIC KEYPAD LOCK OPTIONAL ATTACHMENT MEMO ...
Page 274: ...INDEX 14 4 MEMO ...
Page 276: ......
Page 277: ......
Page 278: ......