MAINTENANCE
7-11
Tank Cover
ZX26U-5A
d
WARNING:
Do not keep the access covers open when the
machine is parked on a slope, or while the wind
is blowing hard. The access covers may close
accidentally, possibly resulting in personal injury.
When opening or closing the access covers, take
extra care not to catch fingers between the base
machine and the access covers.
1. Press button (2) and raise cover (1) to open cover (1).
2. Raise cover (1) until stopper (3) fits into the lock position
on bracket (4).
3. Confirm that stopper (3) is in the LOCK position before
releasing your hands.
d
CAUTION: When closing cover (1), confirm that cover
(1) is securely locked.
4. When closing cover (1), push stopper (3) while raising
cover (1) by hand.
5. Lower cover (1) while pushing stopper (3). Release
stopper (3) when cover (1) is lowered by 1/4 of its
movable distance.
f
NOTE: Button (2) can be locked with the key.
MADB-07-005
MADB-07-006
1
Unlock
Position
LOCK
Position
MABA-07-010
2
MABA-07-011
4
3
Summary of Contents for Zaxis 17U-5A
Page 4: ......
Page 8: ...CONTENTS MEMO ...
Page 12: ...MACHINE NUMBERS 4 MEMO ...
Page 84: ...OPERATOR S STATION 1 18 MEMO ...
Page 86: ...BREAK IN 2 2 MEMO ...
Page 108: ...DRIVING THE MACHINE 4 14 MEMO ...
Page 228: ...MAINTENANCE 7 88 MEMO ...
Page 230: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 2 MEMO ...
Page 232: ...STORAGE 10 2 MEMO ...
Page 240: ...TROUBLESHOOTING 11 8 MEMO ...
Page 250: ...SPECIFICATIONS 12 10 MEMO ...
Page 270: ...13 20 NUMERIC KEYPAD LOCK OPTIONAL ATTACHMENT MEMO ...
Page 274: ...INDEX 14 4 MEMO ...
Page 276: ......
Page 277: ......
Page 278: ......