Chapter 4 Performing CCI Operations
Table 4.33 lists information about the different journal volume statuses. QCNT=0 indicates
that the number of remaining Q-Markers is ‘0’. The letter ‘N’ indicates a non-zero.
Table 4.33 Detailed Status of the Journal Volume
JNLS Other
Information
P-JNL S-JNL QCNT AP
Description
0
-
Configured as journal volume, but NOT pair
SMPL
N
-
Deleting the journal volume
PJNN
(PJNS)
SJNN
(SJNS)
0
-
Normal state of the journal volume without data
PJNN
(PJNS)
-
N
-
Normal state of the journal volume with data
N
Normal state of the journal volume with data
- SJNN
(SJNS)
N
0
Still normal state of the journal volume at Link failure
0
-
Suspended journal volume via operation
PJSN SJSN
N
-
Suspending the journal volume
PJNF
-
N
-
High water mark state
0
-
Suspended journal volume due to full journal
PJSF SJSF
N
-
Suspending the journal volume due to full journal
0
-
Suspended journal volume due to failure/Link failure
PJSE -
N
-
Suspending the journal volume due to failure/Link failure
N
Suspended journal volume due to failure
0
0
Suspended journal volume due to Link failure
N
Suspending the journal volume due to failure
- SJSE
N
0
Suspending the journal volume due to Link failure
# raidvchkscan -v jnlt
JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# DOW PBW APW
001 0 1 PJNN 4 21 43216fde 30 512345 63528 20 300 40
002 1 2 PJNF 4 95 3459fd43 52000 512345 63528 20 300 40
003 0 3 PJSN 4 0 - - 512345 63528 20 300 40
Figure 4.48 Raidvchkscan Command Example with -v jnlt Option
Output of the
raidqvchkscan
command with
-v jnlt
option:
DOW
: This shows “Data Overflow Watch” timer (in unit of Sec.) setting per the Journal
group.
PBW
: This shows “Path Blockade Watch” (in unit of Sec.) timer setting per the Journal
group. Also this will be shown as “0” on “SMPL” state.
APW
: This shows “Active Path Watch” timer (in unit of Sec.) for detecting Link failure.
Summary of Contents for TAGMASTORE MK-90RD011-25
Page 2: ......
Page 8: ...viii Preface ...
Page 18: ...xviii Contents ...
Page 180: ...162 Chapter 3 Preparing for CCI Operations ...
Page 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Page 370: ...352 Chapter 5 Troubleshooting ...
Page 388: ...370 Acronyms and Abbreviations ...