Hitachi Command Control Interface (CCI) User and Reference Guide
197
Table 4.14 Specific Error Codes for Pairvolchk
Category
Error Code
Error Message
Recommended Action
Value
Volume status
EX_ENQVOL
Unmatched volume status
within the group
Confirm status using the pairdisplay
command. Make sure all volumes in the
group have the same fence level and volume
attributes.
236
Unrecoverable EX_EVOLCE
Pair Volume combination error
Confirm pair status using pairdisplay, and
change combination of volumes.
235
Note:
Unrecoverable errors are fixed and will not be resolved, even after re-executing the
command. If the command failed, the detailed status will be logged in the CCI command log
($HORCC_LOG) (see Table A.2), even if the user script has no error handling.
Summary of Contents for TAGMASTORE MK-90RD011-25
Page 2: ......
Page 8: ...viii Preface ...
Page 18: ...xviii Contents ...
Page 180: ...162 Chapter 3 Preparing for CCI Operations ...
Page 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Page 370: ...352 Chapter 5 Troubleshooting ...
Page 388: ...370 Acronyms and Abbreviations ...