Chapter 3 Preparing for CCI Operations
3.3.5
Changing the CCI User (Windows Systems)
Usually, RAID Manager commands can only be executed by the system administrator in order
to directly open the PhysicalDrive.
When an administrator of CCI does not have an “administrator” privilege or there is a
difference between the system administrator and the CCI administrator, the CCI
administrator can use CCI commands as follows:
System Administrator Tasks
1.
Add a user_name to the PhysicalDrive.
Add the user name of the CCI administrator to the Device Objects of the command
device for HORCM_CMD in the configuration definition file. For example:
C:\HORCM\tool\>chgacl /A:RMadmin Phys
PhysicalDrive0 -> \Device\Harddisk0\DR0
\\.\PhysicalDrive0 : changed to allow ‘RMadmin’
2.
Add a user_name to the Volume{GUID}.
If the CCI administrator needs to use the “-x mount/umount” option for CCI commands,
the system administrator must add the user name of the CCI administrator to the Device
Objects of the Volume{GUID}. For example:
C:\HORCM\tool\>chgacl /A:RMadmin Volume
Volume{b0736c01-9b14-11d8-b1b6-806d6172696f} -> \Device\CdRom0
\\.\Volume{b0736c01-9b14-11d8-b1b6-806d6172696f} : changed to allow ‘RMadmin’
Volume{b0736c02-9b14-11d8-b1b6-806d6172696f} -> \Device\Floppy0
\\.\Volume{b0736c02-9b14-11d8-b1b6-806d6172696f} : changed to allow ‘RMadmin’
Volume{b0736c00-9b14-11d8-b1b6-806d6172696f} -> \Device\HarddiskVolume1
\\.\Volume{b0736c00-9b14-11d8-b1b6-806d6172696f} : changed to allow ‘RMadmin’
3.
Add a user_name to the ScsiX.
If the CCI administrator needs to use the “-x portscan” option for CCI commands, the
system administrator must add the user name of the CCI administrator to the Device
Objects of the ScsiX. For example:
C:\HORCM\tool\>chgacl /A:RMadmin Scsi
Scsi0: -> \Device\Ide\IdePort0
\\.\Scsi0: : changed to allow ‘RMadmin’
Scsi1: -> \Device\Ide\IdePort1
\\.\Scsi1: : changed to allow ‘RMadmin ‘
Note:
Because the ACL (Access Control List) of the Device Objects is set every time Windows
starts-up, the Device Objects are also required when Windows starts-up. The ACL is also
required when new Device Objects are created.
Summary of Contents for TAGMASTORE MK-90RD011-25
Page 2: ......
Page 8: ...viii Preface ...
Page 18: ...xviii Contents ...
Page 180: ...162 Chapter 3 Preparing for CCI Operations ...
Page 250: ...232 Chapter 4 Performing CCI Operations Vol Type logical unit LU type e g OPEN V OPEN 9 ...
Page 370: ...352 Chapter 5 Troubleshooting ...
Page 388: ...370 Acronyms and Abbreviations ...