ModBus Data Listing
Appendix B
B–24
The table below lists the holding registers for the “F” Group Main Profile Parameters.
Note 1:
When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored.
Holding Registers, “F” Group Main Profile Parameters
Func.
Code
Name
R/W
Description
Network Data
Reg.
Range
Res.
F001
Output frequency
setting
R/W Standard default target
frequency that determines
constant motor speed,
range is 0.0 / start frequency
to 400 Hz
0023h
0 / (start
freq. x 10)
to 4000
0.1 Hz
F002
(high)
Acceleration (1) time
setting *1
R/W Standard default acceleration,
range is 0.01 to 3000 sec.
0024h
1 to
300000
0.01
sec
F002
(low)
R/W
0025h
F202
(high)
Acceleration (1) time
setting, 2nd motor *1
R/W Standard default acceleration,
2nd motor,
range is 0.01 to 3000 sec.
0026h
1 to
300000
0.01
sec
F202
(low)
R/W
0027h
F003
(high)
Deceleration (1) time
setting *1
R/W Standard default deceleration,
range is
0.01 to 3000 sec.
0028h
1 to
300000
0.01
sec
F003
(low)
R/W
0029h
F203
(high)
Deceleration (1) time
setting, 2nd motor *1
R/W Standard default deceleration,
2nd motor,
range is 0.01 to 3000 sec.
002Ah
1 to
300000
0.01
sec
F203
(low)
R/W
002Bh
F004
Keypad Run key routing R/W Two options; select codes:
00... Forward
01... Reverse
002Ch
0, 1
—