SJ200 Inverter
Appendix B
B–39
Note 1:
Assume that the inverter current rating is 10000 (for C041).
The following table lists the holding registers for the “H” Group Motor Constants.
C146
Terminal [12] ON delay
R/W Range is 0.0 to 100.0 sec.
00F4h
0 to 1000
0.1 sec
C147
Terminal [12] OFF
delay
R/W Range is 0.0 to 100.0 sec.
00F5h
0 to 1000
0.1 sec
C148
Output relay ON delay
R/W Range is 0.0 to 100.0 sec.
00F6h
0 to 1000
0.1 sec
C149
Output relay OFF delay
R/W Range is 0.0 to 100.0 sec.
00F7h
0 to 1000
0.1 sec
“C” Group Intelligent Terminal Functions
Func.
Code
Name
R/W
Description
Network Data
Reg.
Range
Res.
“H” Group Motor Constants
Func.
Code
Name
R/W
Description
Network Data
Reg.
Range
Res.
H003
Motor capacity
R/W Thirteen selections:
0..... 0.20 kW
1..... 0.37 kW
2..... 0.40 kW
3..... 0.55 kW
4..... 0.75 kW
5..... 1.10 kW
6..... 1.50 kW
7..... 2.2 kW
8..... 3.0 kW
9..... 3.7 kW
10... 4.0 kW
11... 5.5 kW
12... 7.5 kW
00D9h
0 to 12
—
H203
Motor capacity, 2nd
setting
R/W
00DAh
0 to 12
—
H004
Motor poles setting
R/W Four selections:
2 / 4 / 6 / 8
00DBh
2, 4, 6,
8
1 pole
H204
Motor poles setting, 2nd
motor
R/W
00DCh
2, 4, 6,
8
1 pole
H006
Motor stabilization
constant
R/W Motor constant (factory set),
range is 0 to 255
00DDh 0 to 255
1
H206
Motor stabilization
constant, 2nd motor
R/W
00DEh
0 to 255
1
H007
Motor voltage select
R/W Two selections, option codes:
00... 200V
01... 400V
00DFh
0, 1
—
H207
Motor voltage select,
2nd motor
R/W
00E0h
0, 1
—