5 Optional functions
Optional functions through Remote control
SMGB0137 rev.0 - 05/2021
143
5
Item
Optional function
Individual
Setting
Settings
Setting conditions
Description
bg
Locking of fan
speed setting
(Not available for
models KPI-E4)
×
00
Function disabled
(factory setting)
This function prevents the
modification of the fan speed of the
unit from the remote controller and
from central controls, once it has
been selected.
01
Function enabled
bA
Not available
-
“- -”
permanent Not available
–
bb
Cooling setting
temperature
correction
×
00
No compensation (factory setting)
This function decreases the setting
temperature and is used to produce
longer cooling periods.
01
Setting temperature decreased by
1 ºC
02
Setting temperature decreased by
2 ºC
bC
Not used
-
00
-
Use at 00 conditions
01
bd
Not used
-
00
-
Use at 00 conditions
01
bE
Not used
-
00
-
Use at 00 conditions
01
C1
Not used
-
00
-
Use at 00 conditions
01
C2
Not available
-
“- -”
permanent -
–
C3
Not used
-
00
-
Use at 00 conditions
01
Only for DX-
Interface, KPI-E4E
and KPI-X4E:
Fan stoppage delay
00
Function disabled
(factory setting)
This function keeps the fan in
operation for 60 minutes after stop of
the KPI unit or DX-Interface.
01
60 minutes
C4
Not used
-
00
-
Use at 00 conditions
01
C5
Static pressure
selection
Models
RPI(L/H)-FSRE
RPI-FSN3(P)E(-f)
○
00
Standard static pressure
(factory setting)
This function is used to change the
static pressure of the RPI units from
the remote control.
01
High static pressure
02
Low static pressure
Increase of fan
speed during normal
operation (not during
heating Thermo-
OFF)
Models
RCI-FSR
RCIM-FSRE
RCD-FSR
RPC-FSR
RPK-FSR(H)M
RPF(I)-FSN2E
○
00
Standard
(factory setting)
This function is used to change the
fan speed of indoor units installed in
high ceilings.
01
Hi Speed 1
02
Hi Speed 2
Fan speed setting on the remote controller
C5
High H
High
Medium
Low
0
Hi2
Hi
Me
Lo
1
Hi2
Hi1
Hi
Me
2
Hi2
Hi2
Hi1
Hi
(This function C5 is not available for DX-Interface models)