Chapter 3
Interface with the Inverter
3.1 Inverter
Settings
The following table lists the inverter settings related to the easy sequence function.
(1)SJ700/L700/SJ700B Series
Category
Item
Variable notation
in program
Related function
code
Variable/
terminal use condition
Terminal name
Operation
switching
Selection of easy sequence function
-
A017
-
Input/
output
switching
Program run signal
PRG(FW terminal)
-
A017
The PRG terminal is enabled when
A017 = 01.
(The FW function is disabled.)
General-purpose input
contacts (8 contacts)
Intelligent input
terminals
1 to 8
X (00) to X (07)
Xw
C001 to C008
Function code settings are required.
General-purpose output
contacts (6 contacts)
Intelligent output
terminals
11 to 15
Y (00) to Y (05)
Yw
C021 to C025
Intelligent relay output
terminals
AL0 to AL2
C026
General-purpose analog
inputs (3 terminals)
O terminal
XA (0)
-
No setting is required.
OI terminal
XA (1)
-
O2 terminal
XA (2)
-
General-purpose analog
outputs (3 terminals)
FM terminal
YA (0)
C027
Function code settings are required.
AM terminal
YA (1)
C028
AMI terminal
YA (2)
C029
Command
switching
Frequency command selection
SET-Freq
A001
Related variables are valid only
when A001 = 07.
Operation command selection
FW, RV
STA, STP, F/R
A002
Related variables are valid only
when A002 = 01.
Acceleration/deceleration input selection
ACCEL,
DECEL
P031
Related variables are valid only
when P031 = 03.
Other
User-defined variables (32 variables)
U(00)
㨪
U(31) P100
㨪
P131
The variables can be redefined by
using the digital operator or EzSQ.
3-1
Eight digital output terminals
Three analog
output terminals
0 to 10V
3-phase power supply
(200 or 400 V)
Three analog
input terminals
PRG
(setting unchangeable)
Selecting
MI1
X (00)
FW
1
2
3
4
5
6
7
8
CM1
H
O
O2
OI
L
0 to 10V
4 to 20mA
XA (00)
XA (01)
XA (02)
CM2
11
12
13
14
15
AL0
AL1
AL2
CM1
FM
AM
AMI
L
Selecting
MO1
Y (00)
Selecting
YA0
YA (00)
Selecting
YA1
YA (01)
Selecting
YA2
YA (02)
I
M
Selecting
MI2
X (01)
Selecting
MI3
X (02)
Selecting
MI4
X (03)
Selecting
MI5
X (04)
Selecting
MI6
X (05)
Selecting
MI7
X (06)
Selecting
MI8
X (07)
Selecting
MO2
Y (01)
Selecting
MO3
Y (02)
Selecting
MO4
Y (03)
Selecting
MO5
Y (04)
Selecting
MO6
Y (05)
R
S
T
U
V
W
SJ700/L700/SJ700B Series
Five digital
output terminals
One relay
output terminal
Input and output terminals available for general-purpose input / output settings
Summary of Contents for NT2021XA
Page 4: ... Safety Instructions ...
Page 8: ... Contents ...
Page 10: ...Chapter 1 Outline of EzSQ ...
Page 14: ...1 4 Chapter 1 Outline of EzSQ ...
Page 16: ...Chapter 2 Syntax ...
Page 68: ...2 52 Chapter 2 Syntax ...
Page 70: ...Chapter 3 Interface with the Inverter ...
Page 80: ...3 10 Chapter 3 Interface with the Inverter ...