1-1
Chapter 1
Outline of EzSQ
1.1 Outline
Easy sequence function (EzSQ) can built a simple sequence function by making the program with programming
software ProDriveNext. In the program, it is possible to change the I/O function and the parameter setting value.
1.2 Corresponding
Model
- SJ700 series
- WJ200 series
- L700 series
- SJ700B series
1.3 Specifications
The table below lists the programming-related specifications of the easy sequence function.
㩷
Item Specification
Language
s
p
e
c
if
ic
a
ti
o
n
Programming language
Basic-like language
Input device
Windows (DOS/V) personal computer (OS:Windows2000,WindowsXP)
Max. program size
1024steps
(The internal storage capacity of the inverter is 1024 steps or 6144 bytes.)
Programming support
function (programming
software)
- Editing (on Windows) / - Display (on Windows)
- Program syntax check (on Windows)
- Downloading, uploading, and full clearance of program
Execution format
Execution by interpreter in an execution cycle of 2 ms per instruction
(possible subroutine call with nesting in up to 8 layers)
Input
/o
u
tput
-rel
at
ed f
unct
ions
External input
Contact signal
24 V open-collector input (using intelligent input terminals)
Program run signal input
SJ700/L700/SJ700B : Always assigned to the FW terminal
WJ200 : Assign to the PRG terminal / Always run
Program run signal input
SJ700/L700/SJ700B : Up to 8 terminals (X (00) to X (07))
WJ200 : Up to 8 terminals (X (00) to X (07))
General-purpose analog input
XA (0): 0 to 10 V (O terminal)
XA (1): 4 to 20 mA (OI terminal)
XA (2): 0 to 10 V (O2 terminal) (Only SJ700)
External output
General-purpose output terminal
SJ700/L700/SJ700B : Up to 6 terminals (Y (00) to Y (05))
WJ200 : Up to 3 terminals (Y (00) to Y (02))
General-purpose analog output
YA (0): Assignable to the FM terminal
YA (1): Assignable to the AM terminal
YA (2): Assignable to the AMI terminal (Only SJ700)
Res
erv
ed words
Instructions
(1)
Program control instructions
- Loop (for) / - Unconditional branching (goto) / - Time control (wait)
- Conditional branching (if then, ifs then, select case, until, and while)
- Subroutine (call, sub) / - Others (entry, end, cont, inc, and dec)
(2) Arithmetic instructions
- Arithmetic operation (+, -, *, /) / - Remainder (mod) / - Substitution (=)
- Absolute value (abs) / - Logic operation (or, and, xor, and not)
(3)
Input/output control
- General-purpose input/output (bit input, word input, bit output, and word output)
- Reading of inverter input terminal
(4) Timer control : - Delay operation / - Timer control
(5) Parameter control : - Rewriting of parameters by reselecting code on the operator's display
Number of variables
User-defined variable
U (00) to U (31) (32 variables)
Internal user variable
UL (00) to UL (07) (8 variables)
Set frequency
SET-Freq
Acceleration time
ACCEL
Deceleration time
DECEL
Monitoring variable
FM, Iout, Dir, PID-FB, F-CNV, Tmon, Vout, Power,
RUN-Time, ON-Time, PlsCnt (Only SJ700/L700/SJ700B),
POS, STATUS, DCV, ERR CNT, ERR(1), ERR(2), ERR(3),
ERR(4), ERR(5), and ERR(6)
General-purpose input contact
SJ700/L700/SJ700B : X (00) to X (07) (8 contacts)
WJ200 : X (00) to X (07) (8 contacts)
General-purpose output contact
SJ700/L700/SJ700B : Y (00) to Y (05) (6 contacts)
(including a relay contact output)
WJ200 : Y (00) to Y (02) (3 contacts)
(including a relay contact output)
Internal user contact
UB (00) to UB (07) (8 contacts)
Internal timer contact
TD (0) to TD (7) (8 contacts)
Inverter input/output
Specification by code on the remote operator's display
User monitor
Umon (00) to Umon (02) (3 variables)
User trip
Makes the inverter trip (10 variables)
Summary of Contents for NT2021XA
Page 4: ... Safety Instructions ...
Page 8: ... Contents ...
Page 10: ...Chapter 1 Outline of EzSQ ...
Page 14: ...1 4 Chapter 1 Outline of EzSQ ...
Page 16: ...Chapter 2 Syntax ...
Page 68: ...2 52 Chapter 2 Syntax ...
Page 70: ...Chapter 3 Interface with the Inverter ...
Page 80: ...3 10 Chapter 3 Interface with the Inverter ...