An optional remote plug is available to enable remote
controlling of the BW MODE and scene file. The plug is wired as
shown in the figure and connected to the remote connector of
the camera rear panel.
Remote-contact switch connections
Confirm the switches are wired as indicated in the figure.
The menu can not be displayed when this plug is connected.
Turn off power when connecting the plug.
Camera rear panel key switches can not be used when
remote-contact is connected.
44
Remote-contact operation
Remote-contact [SCENE_FILE]
43
Note
1) When the plug is connected, remote operation has priority.
2) White pixels may appear in the image at high sensitivity. It
is not a defect.
3) The CCD storage time increases at high sensitivity and
blurring might be occurred with moving objects.
N.C.
①
N.C.
②
N.C.
③
D0
④
D1
⑤
D2
⑥
D3
⑦
N.C.
⑧
N.C.
⑨
N.C.
⑩
REMOTE
⑪
GND
⑫
Pin No.
Signal
Code
Remarks
1
N.C.
N.C.
Do not connect
2
N.C.
N.C.
Do not connect
3
N.C.
N.C.
Do not connect
4
D0
D0
Scene file setting switch
5
D1
D1
Scene file setting switch
6
D2
D2
Scene file setting switch
7
D3
D3
Scene file setting switch
8
N.C.
N.C.
Do not connect
9
N.C.
N.C.
Do not connect
10
N.C.
N.C.
Do not connect
11
REMOTE
REMOTE
Connect to 12 pin(GND)
12
GND
GND
GND
Scene file setting
D3
D2
D1
D0
File
0
0
0
0
FILE 1
0
0
0
1
FILE 2
0
0
1
0
FILE 3
0
1
0
0
FILE 4
1
0
0
0
FILE 5
Default
FILE 1
1
:
SW ON (close)
0
:
SW OFF (open)
In this case D0, D1, D2 and D3 terminals are used to change
the scene file.
Contact specification of terminals is as follows.
Note
Do not use camera rear panel key switches when remote
is connected, it may cause errors.
N.C.
N.C.
GND
REMOTE
N.C.
N.C.
D3
EXTVD/D2
EXTVD/D1
D0
(Viewed from connecting side)
HR-10A-10P-12P(01) HRS