Component Details
GR2K-GA-1002
3-21
Rev. 6.03
3.5.3
NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA
The NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA physically appear as Figure 3-24.
These NIFs each have one port for connection with a pair of SC 2-core optical fiber
connectors (transmit and receive). Table 3-20 shows the connector specifications.
Figure 3-24 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1SB, NE1G-1LB and NE1G-1LHBA Front Panel View
Switch and LED indication
Table 3-19 NE1G-1S, NE1G-1SA, NE1G-1L, NE1G-1LA, NE1G-1LHA, NE1G-1LHA8,
NE1G-1LB, NE1G-1SB and NE1G-1LHBA switch and function of LED
indications
Name
Name of switch
and LED
Status
Content
STATUS
LED: Green/
Yellow/ Red
Shows the operating
condition of RM.
Green: Operable operation
Yellow: Blocking and the board replaceable state.
Green blinking: Under preparation (Program being
loaded.)
Red: Fault
Extinguished: Operation not possible (Including the
device power supply being turned off)
LINE
LED: Green
Green: Ring pulse being established
ACT
LED: Green
Shows the operating
condition of each line.
Green: Line operation possible state (line open state)
LINE ERR
LED: Yellow
Yellow: Line section II/W fault detection.
R
LED: Green
Frame signal being received.
T
LED: Green
Frame signal being transmitted.
SIG-DT
LED: Green
Signal detect operation detected.
R
T
SIG-DT
LINK
ACT
LINE ERR
ST
AT
U
S
NE
1
G
-1
**
LINE 0
T
R
1000BASE-SX or
1000BASE-LX or
1000BASE-LH
Mark ** indicates 1S, 1SA, 1SB, 1L,
1LA, 1LB, 1LHA, 1LHAB, and 1LHBA.
Summary of Contents for GR2000 Series
Page 1: ...Hitachi Gigabit Router GR2000 Series GR2K GA 1002 Rev 6 03 Installation Guide ...
Page 26: ...GR2000 Installation Guide xxvi GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 42: ...GR2000 Installation Guide xlii GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 54: ...GR2000 Installation Guide liv GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 102: ...GR2000 Installation Guide 2 46 GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 296: ......
Page 312: ... n upper eft side In upper right side In upper front end ...
Page 314: ......
Page 329: ......
Page 330: ... ...
Page 338: ... Metal bracket accessory of rack 19 inch rack Interface cable Power calbe ...
Page 345: ...19 inch Rack GR2000 10H or GR2000 10 Guide Rail ...
Page 350: ......
Page 351: ...547 95 177 8 1430 133 35 177 8 ...
Page 353: ...19 inch Rack GR2000 20H or GR2000 20 Guide Rail ...
Page 356: ...Metal fittings supplied as accessories M4 screws supplied as accessories NIF side ...
Page 359: ...Connect both power cables if there is a redundant power supply Power Switch I O ...
Page 364: ...Breaker switch I O L N Terminal board Front ...
Page 369: ... Breaker switch I O Front Rear ...
Page 384: ......
Page 386: ... ...
Page 387: ... ...
Page 388: ... Anchor screw Guide rail ...
Page 393: ...2 Follow the instructions illustrated in Figure 8 5 I O DC DC unit power switch ...
Page 395: ...2 Follow the instruction illustrated in Figure 8 7 I O DC DC unit power switch ...
Page 398: ...POW 2 Follow the instructions illustrated in Figure 8 10 Using the latches ...
Page 410: ......