Component Details
GR2K-GA-1002
3-23
Rev. 6.03
Table 3-22 NWVX-4 LINE LED indication
Act
(*1)
LINE
ERR
(*1)
T/R
(*1)
Line state
Detail of state
State as seen by
SXMP
Line state indication
in MMI and browser
--
--
(*3)
Being initialized.
Being initialized (3).
initialize
G
--
(*3)
Being operated
In normal operation.
In standby (3).
active up
--
Y
(*3)
Line fault being
occurred.
In operation (line fault
being occurred (8).
active down
G
--
(*3)
Line test.
Line being tested (9).
test
--
--
--
In fault.
In fault (4).
fault
--
--
--
Command being
blocked.
In maintenance (7).
closed
--
--
--
Not used.
Configuration
definition not set yet
Not used.
Configuration definition
not set yet. (10)
unused
--
--
--
Configuration
definitions not
agreed.
Configuration definitions
not agreed. (11)
mismatch
(*1): G: Lights in green, Y: Lights in yellow, -: Goes off
(*2): Meaning and value of SMNP private MIB and gr2kPhysLineOperStatus
(*3): The T/R LED lights and goes off by H/W. In lighting conditions, this LED lights in green when the logical value of
send and receive data is "0". The LED lights in green when lighting conditions are detected irrespective of the line
state.
Table 3-23
Connector Specifications for NWVX-4, Pin Assignment for V.24
WAN 25-pin (Male)
Connection Router 50-pin
Specifications
2
—————
9
SD (send data) (output)
3
—————
10
RD (receive data) (input)
4
—————
15
RS (request to send) (output)
5
—————
16
CS (clear to send) (input)
6
—————
12
DR (date set ready) (input)
7
—————
34
SG (signal ground)
8
—————
30
CD (carrier detect of data channel receive) (input)
15
—————
22
ST2 (send element timing 2) (input)
17
—————
32
RT (receive element timing) (input)
18
—————
13
LLB (output)
20
—————
11
ER (data terminal ready) (output)
21
—————
23
RLB (output)
22
—————
24
Ci (call indicator) (input)
24
—————
31
ST1 (send element timing 1) (output)
25
—————
14
Ti (test indicator) (input)
1
—————
shell
FG (frame ground)
43 -44
Connection is required if the router is DTE.
Separate contact is required if it is DCE.
45 -46
5 - 6
Summary of Contents for GR2000 Series
Page 1: ...Hitachi Gigabit Router GR2000 Series GR2K GA 1002 Rev 6 03 Installation Guide ...
Page 26: ...GR2000 Installation Guide xxvi GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 42: ...GR2000 Installation Guide xlii GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 54: ...GR2000 Installation Guide liv GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 102: ...GR2000 Installation Guide 2 46 GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 296: ......
Page 312: ... n upper eft side In upper right side In upper front end ...
Page 314: ......
Page 329: ......
Page 330: ... ...
Page 338: ... Metal bracket accessory of rack 19 inch rack Interface cable Power calbe ...
Page 345: ...19 inch Rack GR2000 10H or GR2000 10 Guide Rail ...
Page 350: ......
Page 351: ...547 95 177 8 1430 133 35 177 8 ...
Page 353: ...19 inch Rack GR2000 20H or GR2000 20 Guide Rail ...
Page 356: ...Metal fittings supplied as accessories M4 screws supplied as accessories NIF side ...
Page 359: ...Connect both power cables if there is a redundant power supply Power Switch I O ...
Page 364: ...Breaker switch I O L N Terminal board Front ...
Page 369: ... Breaker switch I O Front Rear ...
Page 384: ......
Page 386: ... ...
Page 387: ... ...
Page 388: ... Anchor screw Guide rail ...
Page 393: ...2 Follow the instructions illustrated in Figure 8 5 I O DC DC unit power switch ...
Page 395: ...2 Follow the instruction illustrated in Figure 8 7 I O DC DC unit power switch ...
Page 398: ...POW 2 Follow the instructions illustrated in Figure 8 10 Using the latches ...
Page 410: ......