Product Overview
GR2K-GA-1002
2-29
Rev 6.03
2.4.1
Cabinet (Network Processor Unit Chassis)
Each model of the GR2000 family has its own cabinet that includes one or more fans
for cooling. See Figures 2-1 thru 2-24 in 2.2 for their external images.
2.4.2
Basic Control Unit (BCU)
The components of the BCU vary depending on the GR2000 models as shown below.
Table 2-2
Each cabinet and maximum number of modules that can be mounted Device
Cabinet
Device
cabinet
Constituting element
Maximum number of
modules that can be
mounted
Remarks
GR2000-2S
BCU (RM-CPU and RMP)
1 (Built in. )
Corresponding to RP-A1.
1 (Built in. )
NIF
2
PS
1 (Built in. )
GR2000-4S
BCU (RM)
1
RP
1
NIF
4
PS
2
Possible of duplication.
GR2000-6H
BCU (RM and CSW)
2
Possible of duplication.
RP
3
NIF
6
PS
2
Possible of duplication.
GR2000-10H
BCU (RM and CSW)
2
Possible of duplication.
RP
5
NIF
10
PS
4
GR2000-20H
BCU (RM)
2
Possible of duplication.
CSW
2
Possible of duplication.
RP
10
NIF
20
PS
6
Possible of duplication.
Table 2-3
Abbreviation for BCU model names and configuration of each device
Device cabinet
Abbreviation for
BCU model name
Configuration
GR2000-2S
Built in cabinet
•
RM-CPU(2S) board
•
RMP boards (to handle RM-IO, RP-A1, 10BASE-T/
100BASE/TX (4 boards) are built in).
GR2000-4S
BDU-S300S
•
RM-CPU (4S) board
•
RM-IO (4S) board
GR2000-6H
BCU-H300H
•
RM-CPU (HH) board
•
RM-IO (H) board (Built-in 4x4 cross bar switch)
BCU-H850H
•
RMB-CPU (HH) board
•
RMB-IO (H) board (Built in 4x4 cross bar switch)
Summary of Contents for GR2000 Series
Page 1: ...Hitachi Gigabit Router GR2000 Series GR2K GA 1002 Rev 6 03 Installation Guide ...
Page 26: ...GR2000 Installation Guide xxvi GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 42: ...GR2000 Installation Guide xlii GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 54: ...GR2000 Installation Guide liv GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 102: ...GR2000 Installation Guide 2 46 GR2K GA 1002 Rev 6 03 This page left intentionally blank ...
Page 296: ......
Page 312: ... n upper eft side In upper right side In upper front end ...
Page 314: ......
Page 329: ......
Page 330: ... ...
Page 338: ... Metal bracket accessory of rack 19 inch rack Interface cable Power calbe ...
Page 345: ...19 inch Rack GR2000 10H or GR2000 10 Guide Rail ...
Page 350: ......
Page 351: ...547 95 177 8 1430 133 35 177 8 ...
Page 353: ...19 inch Rack GR2000 20H or GR2000 20 Guide Rail ...
Page 356: ...Metal fittings supplied as accessories M4 screws supplied as accessories NIF side ...
Page 359: ...Connect both power cables if there is a redundant power supply Power Switch I O ...
Page 364: ...Breaker switch I O L N Terminal board Front ...
Page 369: ... Breaker switch I O Front Rear ...
Page 384: ......
Page 386: ... ...
Page 387: ... ...
Page 388: ... Anchor screw Guide rail ...
Page 393: ...2 Follow the instructions illustrated in Figure 8 5 I O DC DC unit power switch ...
Page 395: ...2 Follow the instruction illustrated in Figure 8 7 I O DC DC unit power switch ...
Page 398: ...POW 2 Follow the instructions illustrated in Figure 8 10 Using the latches ...
Page 410: ......