OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 152 / 313
The Address of First Failure field contains information that locates the failure on
the media. If the logical unit implements logical blocks, the content of the Address
of First Failure field is the first logical block address where a self-test error
occurred. This implies nothing about the quality of any other logical block on the
logical unit, since the testing during which the error occurred may not have been
performed in a sequential manner. This value shall not change. The content of the
Address of First Failure field shall be FFFFFFFFFFFFFFFF
H
if no errors occurred
during the self-test or if the error that occurred is not related to an identifiable
media address.
The Sense Key, Additional Sense Code, and Additional Sense Code Qualifier field
may contain a hierarchy of additional information to error or exception conditions
that occurred during the self-test represented in the same format used by sense
data.
Informational Exceptions Page (Page Code = 2F
H
)
Table 6-36 Informational Exceptions Page (Page Code = 2F
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code
0
0
1
0
1
1
1
1
1
Reserved
0
0
0
0
0
0
0
0
2
(MSB)
Page Length (0008
H
)
3
(LSB)
4
(MSB)
Parameter Code (0000
H
)
5
(LSB)
6
DU
DS
TSD
ETC
TMC
LBIN
LP
0
0
0
0
0
0
7
Parameter Length (04
H
)
8
Informational Exception Additional Code
(cont’d)
LOG SELECT:(4Ch)