OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 173 / 313
Table 6-42 Format Device Page (Page Code = 3
H
) (Cont`d)
SECTOR FORMAT FIELDS
12
Data Bytes per Physical Sector (MSB)
13
Data Bytes per Physical Sector (LSB)
14
Interleave (MSB) (00
H
)
0
0
0
0
0
0
0
0
15
Interleave (LSB) (01
H
)
0
0
0
0
0
0
0
1
16
Track Skew Factor (MSB)
17
Track Skew Factor (LSB)
18
Cylinder Skew Factor (MSB)
19
Cylinder Skew Factor (LSB)
DRIVE TYPE FIELD
20
SSEC
HSEC
RMB
SURF
Reserved
0
0
0
0
0
0
0
21
Reserved
0
0
0
0
0
0
0
0
22
Reserved
0
0
0
0
0
0
0
0
23
Reserved
0
0
0
0
0
0
0
0
The following information should be sent to the controller prior to the execution of
the FORMAT UNIT command.
After changing these parameters, a FORMAT UNIT command must be sent for the
changes to take effect.
< Handling of defects fields >
The Tracks per Zone field specifies the size in tracks of the zone for the purpose of
allocating alternate spare sectors in zones. The host computer must set this field
to 1.
MODE SELECT:(15h)