OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 121 / 313
The ISO Version (International Standard Organization Version) field is loaded with
code 0
H
and indicates that the controller does not conform with the ISO version
specification.
The ECMA Version (European Computer Manufacture Association Version) field is
loaded with code 0
H
and indicates that the controller does not conform with the
ECMA Version specification.
The ANSI Version field is loaded with code 3
H
and indicates that the controller
conforms with the SCSI-2 version.
The AENC (Asynchronous Event Notification Capability) bit is set to 0 and indicates
that the controller does not support the asynchronous event notification function.
The Trm IOP (Terminate I/O Process) bit is set to 0 and indicates that the controller
does not support the TERMINATE I/O PROCESS message.
The Response Data Format field is loaded with code 2
H
and indicates that the
controller conforms with the ANSI SCSI-2 specifications.
The Additional Length field is loaded with code 6B
H
and indicates that the additional
parameters is consisted of 107 bytes. This field holds the same value, irrespective of
the allocation length stored in the CDB.
The EncServ(Enclosure Services) bit of 0 indicates that the controller does not
support the Enclosure Services Diagnostic pages.The EncServ bit of 1indicatesthat
the controller supports the Enclosure Services Diagnostic pages.
The Port bit is valid in MultiP bit of 1. The Port bit of 0 indicates that the
controller receives INQUIRY command from the port A. The Port bit of 1 indicates
that the controller receives INQUIRY command from the port B.
The MultiP(Multi Port) bit of 0 indicates that the controller is single port device.
The MultiP(Multi Port) bit of 1 indicates that the controller is dual port device.
The Addr16(Wide SCSI Address 16) bit of 0 indicates that the controller does not
support the 16-bit wide SCSI address. The Addr16 bit of 1 indicates that the
controller supports the 16-bit wide SCSI address.
The RelAdr (Relative Address) bit is set to 0 and indicates that the controller does not
support the relative address capability.
The WBus 32 (Wide Bus 32) bit is set to 0 and indicates that the controller does not
support the 32 bits width data transfer.
INQUIRY:(12h)