OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 231 / 313
6.11 READ:(08
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (08
H
)
0
0
0
0
1
0
0
0
1
Logical Unit Number
Logical Block Address (MSB)
2
Logical Block Address
3
Logical Block Address (LSB)
4
Transfer Length
5
Vendor Unique
Reserved
Flag
Link
0
0
0
0
0
0
The READ command transfers to the host computer the number of consecutive data
blocks from the medium specified in the transfer length field starting at the block
address specified in the logical block address field. This command is used to
transfer the latest data written in the specified blocks.
When a 0 is specified in the transfer length field, 256 blocks of data are transferred.
The controller terminates the command with a CHECK CONDITION status and
with the “ILLEGAL REQUEST” sense key an invalid logical block address is
specified (see Note). For other errors, the controller terminates the command
with the CHECK CONDITION status and the appropriate sense key.
Note : The information byte field of the sense data is loaded with the last logical
block address.
READ:(08h)