OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 144 / 313
Table 6-29 Temperature Page(Page Code = D
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code
0
0
0
0
1
1
0
1
1
Reserved
0
0
0
0
0
0
0
0
2
(MSB)
Page Length (6)
3
(LSB)
4
Parameter Code (MSB)
0
0
0
0
0
0
0
0
5
Parameter Code (LSB)
0
0
0
0
0
0
0
0
6
DU
DS
TSD
ETC
TMC
LBIN
LP
1
1
1
7
Parameter Length (2)
8
Reserved
0
0
0
0
0
0
0
0
9
Temperature (Degrees Celsius)
Start-Stop Cycle Counter Page (Page Code = 0E
H
)
This clause defines the optional start-stop cycle counter page(page code 0E
.H
).
A device that implements the start-stop cycle counter page shall implement one or
more of the defined parameters. Table 6-30 shows the start-stop cycle counter page
with all parameters present.
Table 6-30 Start-Stop Cycle Counter Page(Page Code = 0E
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code
0
0
0
0
1
1
1
0
1
Reserved
0
0
0
0
0
0
0
0
(cont
’
d)
LOG SELECT:(4Ch)