OEM MANUAL:K6602771
7 SENSE DATA
Revision: 2 / Date: 2002.12.19
Page: 296 / 313
Table 7-1 Extended Sense Data Format(cont
’
d)
15
SKSV
16
Sense-Key Specific
17
Sense-Key Specific
18
to
Additional Sense Bytes
31
A Valid bit of 1 indicates that the information bytes have been established. A Valid
bit of 0 indicates that no information bytes are established.
The Segment Number field is not used and always indicates 00
H
.
The Filemark bit is not used and always set to 0.
The EOM (End of Medium) bit is not used and always set to 0.
The ILI (Incorrect Length Indicator) bit is set to 1, if the incorrect value is specified
in Byte Transfer Length field at READ LONG or WRITE LONG command.
In other cases, 0 is indicated.
The Sense Key provides the error status information or the exception condition
information. The details of these information are listed in Table 7-2..
The information byte is valid when the Valid bit is set to 1 and the logical block
address associated with the sense key is indicated. The information byte regarding
FORMAT UNIT, READ LONG or WRITE LONG command is to be referred to the
each command description, 6.1, 6.17 or 6.38 respectively.
The Additional Sense Length indicates the number of subsequent sense byte, 24 (18
H
),
which indicates that sense data is 32 bytes.
The Command-Specific Information field indicates the leading logical block address
which could not be reassigned by a REASSIGN BLOCKS command. In other cases,
00000000
H
is indicated.
The Additional Sense Code(ASC) provides the further detail information describing
the sense key and the Additional Sense Code Qualifier(ASCQ) provides the detail
information added to the Additional Sense Code. The details of these information are
given in Table 7-3.