![Hirschmann MACH 1020 User Manual Download Page 55](http://html1.mh-extra.com/html/hirschmann/mach-1020/mach-1020_user-manual_2138010055.webp)
Installation MACH1000
Release 02 03/2013
55
EMC interference
immunity
IEEE 1613:2009
EMI TYPE tests,
test in comp. with
Description
Test level
IEEE C37.90.3
Electrostatic discharge
Contact discharge
± 8 kV
Air discharge
± 15 kV
IEEE C37.90.2
Electromagnetic field
80 MHz ... 1000 MHz
35 V/m (peak)
IEEE C37.90.1
Fast transients (burst)
DC Power Line
± 4 kV
AC Power Line
± 4 kV
Data line
± 4 kV
IEEE C37.90.1
damped oscillation
DC Power Line
± 2,5 kV line/earth; ± 1 kV line/line
AC Power Line
± 2,5 kV line/earth; ± 1 kV line/line
Data line
± 2,5 kV line/earth; ± 1 kV line/line
IEEE C37.90
H.V. Impulse
DC Power Line
± 5 kV line/earth
AC Power Line
± 5 kV line/earth
IEEE C37.90
dielectric strength
DC Power Line, power unit type „C“,
„L“
500 V AC
AC Power Line, power unit type „G“,
„M“
2000 V AC
DC Power Line, power unit type „G“,
„M“
2000 V AC
signal contact type „C“, „L“ and „G“,
„M“
2000 V AC
EMC interference emission
EN 55022
Class A
FCC 47 CFR Part 15 Class A
German Lloyd
Classifi Construction Guidelines VI-7-3 Part 1 Ed.2001
Environment type
tests, test in comp.
with
Description
Test level
IEC 60068-2-1
Cold
−
40 °F (
−
40 °C), 16 hours
IEC 60068-2-2
Dry heat
+185 °F (+85 °C), 16 hours
IEC 60068-2-30
Relative humidity
95 % (non condensing)
131 °F (55 °C), 4 cycles
IEC 60068-2-6
Vibration, test Fc
2 - 9 Hz with 3 mm amplitude
1 g at 9 - 150 Hz
1.5 g at 200 - 500 Hz
IEC 60068-2-27
Shock, test Ea
15 g at 11 ms