![Hirschmann MACH 1020 User Manual Download Page 48](http://html1.mh-extra.com/html/hirschmann/mach-1020/mach-1020_user-manual_2138010048.webp)
48
Installation MACH1000
Release 02 03/2013
Applies to software release 06.0.00 and higher:
If the manual setting is active on the signal contact, then the error display
is independent of the setting of the signal contact.
Port state
The green and yellow LEDs at the individual port display port-related
information. During the boot phase, these LEDs are used to display the
status of the boot procedure.
2.3
Basic set-up
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual on the CD/DVD.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
LED
Display
Color Activity
Meaning
R1
Signal contact 1
Yellow Lights up
The signal contact is open.
None
The signal contact is closed.
R2
Signal contact 2
Yellow Lights up
The signal contact is open.
None
The signal contact is closed.
LS - data, link status (one green/yellow LED or one green and one yellow LED)
Not glowing
No valid connection.
Glowing green
Valid connection.
Flashing green (1 time a period) Port is switched to stand-by.
Flashing green (3 times a
period)
Port is switched off.
Flashing yellow
Data reception.
Summary of Contents for MACH 1020
Page 4: ...4 Installation MACH1000 Release 02 03 2013...
Page 61: ...Installation MACH1000 Release 02 03 2013 61...
Page 62: ...62 Installation MACH1000 Release 02 03 2013...
Page 64: ......