![Hirschmann MACH 1020 User Manual Download Page 53](http://html1.mh-extra.com/html/hirschmann/mach-1020/mach-1020_user-manual_2138010053.webp)
Installation MACH1000
Release 02 03/2013
53
Power supply
types C and L
Rated voltage range DC
24 V ... 48 V
Devices with certification type “T”: 36 V
Voltage range DC incl.
maximum tolerances
18 V ... 60 V
Connection type C
3-pin spring-loaded terminal for copper wire
with cross-section AWG 20-12 (0.5 mm² ... 3.0
mm²) and stripping length 12 mm
Connection type L
3-pin terminal block
Power failure bypass
> 10 ms at 20.4 V DC
Input voltage for
device variants
with PoE
Rated voltage range DC
110 V ... 250 V
Voltage range DC incl.
maximum tolerances
77 V ... 300 V
Rated voltage range AC
110 V ... 230 V
Voltage range AC incl.
maximum tolerances
90 V ... 265 V, 47 Hz ... 63 Hz
Output voltage for
device variants
with PoE
48 V DC ± 5%
Back-up fuse
Power unit types C and G
Nominal rating:
Characteristic:
6.3 A
slow blow
Power unit types L and M
Nominal rating:
Characteristic:
2.5 A
slow blow
Signal contact
Nominal value for AC
I
max
= 2 A at U
max
= 230 V
Nominal value for DC
I
max
= 2 A at U
max
= 30 V
I
max
= 0.2 A at U
max
= 125 V
I
max
= 0.1 A at U
max
= 250 V
Connection type for power
unit types C and G
2-pin spring-loaded terminal for copper wire
with cross-section AWG 20-12 (0.5 mm² ...
3.0 mm²) and stripping length 12 mm
Connection type for power
unit types L and M
2-pin terminal block
Climatic
conditions during
operation
Ambient temperature
Standard
+32 °F ... +140 °F
(0 °C ... +60 °C)
Extended
a b c d e f
−
40 °F ... +185 °F
(
−
40 °C ... +85 °C)
Humidity
5% ... 95%
(non-condensing)
Air pressure
Up to 2000 m (795 hPa), higher altitudes on
request
a. If you are using SFP modules without the “EEC” extension, then an operating temperature
range from +32 °F to +140 °F (0 °C to +60 °C) applies for your device
(see page 59
“Accessories”)
.
b. For devices with an extended temperature range equipped with more than 14 F/O ports, the
maximum operating temperature is reduced by 1 K for each additional F/O port. Example:
MACH1000 device with extended temperature range and 20 F/O ports: Operating
temperature =
−
40 °F to +158 °F (
−
40 °C to +70 °C).
c. MACH1000 device equipped with “GG” Fast Ethernet modules (Singlemode Long Haul FX
DSC 200 km ): +32 °F to +140 °F (0 °C to +60 °C).
d.
−
40 °F to +158 °F (
−
40 °C to +70 °C) for devices with PoE, devices with FL ports and
devices with 4 Gigabit Ethernet ports.
e. Relevant for UL508: maximum operating temperature (ambient air): +158 °F (+70 °C) for
device variants “U8” and “F”, +140 °F (+60 °C) for device variant “S”.
f.
Relevant for explosion hazard areas and certification ISA 12.12.01 Class I, Division 2: The
maximum operating temperature for device variants “U” and “F” is +158 °F (+70 °C) and for
device variant “S” +140 °F (+60 °C) (see page
8 “Environment”
).
Summary of Contents for MACH 1020
Page 4: ...4 Installation MACH1000 Release 02 03 2013...
Page 61: ...Installation MACH1000 Release 02 03 2013 61...
Page 62: ...62 Installation MACH1000 Release 02 03 2013...
Page 64: ......