![Hirschmann MACH 1020 User Manual Download Page 5](http://html1.mh-extra.com/html/hirschmann/mach-1020/mach-1020_user-manual_2138010005.webp)
Installation MACH1000
Release 02 03/2013
5
Safety instructions
Correct usage
Only use the device for those purposes specified in the catalog and in the
technical description. Only operate the device with external devices and
components that are recommended and permitted by the manufacturer.
The proper and safe operation of this product depends on proper handling
during transport, proper storage, assembly and installation, and
conscientious operation and maintenance procedures.
Supply voltage
Note:
The supply voltage is electrically isolated from the housing.
For
every
supply voltage to be connected, make sure the following
requirements are met:
The power supply conforms to overvoltage category I or II.
The voltage supply has an easily accessible disconnecting device
(e.g. a switch or a plug). This disconnecting device is clearly
identified so that in the case of an emergency, it is clear which
disconnecting device belongs to which line.
The disconnecting device is clearly identified so that in the case of
an emergency, it is clear which disconnecting device belongs to
which line.
The lines to be connected are voltage-free.
The ground screw on the back of the device is connected to the
protective conductor.
There is a fuse in the outer conductor (AC) or the positive
conductor (DC) of the voltage supply.
Regarding the properties of this fuse: See “General technical data”
on page 52.
Supply with DC voltage: the fuse is suitable for a DC voltage.
If the neutral conductor (AC) or the negative conductor (DC) is not
grounded: there is a fuse in each of the two wires.
AC voltage Supply: the wire diameter for the input supply line is at
least 0.75 mm² (North America: AWG18).
WARNING
ELECTRIC SHOCK
Only connect a supply voltage as described in the data plate of your device.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.