22
Installation MACH1000
Release 02 03/2013
The power supply unit types have the following different properties:
Type of connections: terminal or plugged
Type of connectable supply voltages: DC or AC voltage
Level of connectable supply voltages:
Note:
To find out which power supply unit type your device has, refer to items
36 and 37 of the product code (see
table 5
on
page
26).
The following tables provide an overview of the possible connections for
voltage-carrying lines:
1 Power supply unit 2
a
a. In devices without PoE, power supply unit 2 is optional. It is used for redundant voltage
supply. In devices with PoE, power supply unit 2 is mandatory. It is only used to supply
PoE voltage to the connected devices.
Possible types:
C
DC voltage connectable
Voltage range: see
page
52
“General technical data”
G
b
b. For devices with PoE that have terminal connections, power supply unit 2 must be type
“G”.
DC or AC voltage connectable
Voltage range: see
page 52
“General technical data”
2 Power supply unit 1
Possible types:
C
See 1
G
See 1
3 Connection for the signal
contact
Spring-loaded terminal
2-pin
4 Connection for the supply
voltage
Spring-loaded terminal
3-pin
5 Grounding screw
Table 3:
Connections for voltage-carrying lines:
rear view of the device variants with terminal connections
4 5
3
2
1
Relay 2
N L
4 5
3
2
1
Relay 1
N L