![Hirschmann MACH 1020 User Manual Download Page 23](http://html1.mh-extra.com/html/hirschmann/mach-1020/mach-1020_user-manual_2138010023.webp)
Installation MACH1000
Release 02 03/2013
23
1 Power supply unit 2
a
a. In devices without PoE, power supply unit 2 is optional. It is used for redundant voltage
supply. In devices with PoE, power supply unit 2 is mandatory. It is only used to supply
PoE voltage to the connected devices.
Possible types:
L
DC voltage connectable
Voltage range: see
page 52
“General technical data”
M
b
b. For devices with PoE that have plugged connections, power supply unit 2 must be type
“M”.
DC or AC voltage connectable
Voltage range: see
page 52
“General technical data”
2 Power supply unit 1
Possible types:
L
See 1
M
See 1
3 Connection for the signal
contact
Spring-loaded terminal
2-pin
4 Connection for the supply
voltage
Spring-loaded terminal
3-pin
5 Grounding screw
Table 4:
Connections for voltage-carrying lines:
rear view of the device variants with plugged connections (above:
MAR11..., below: MAR10...)
Relay 2
3
2
1
4 5
N L
-/N +/L
USB
V.24
MACH 1000
2
1
P
StandBy
RM
FAULT
R1 R2
25
26
23
24
USB
V.24
P
StandBy
RM
FAULT
R1 R2
2
1
-/N +/L
2
5
3
4
1
-/N +/L