- 28 -
Trouble
Cause
Corrective measures
9-5
Screws tend to pass through the passing
plate in an abnormal position.
The axis of the screw thread tends to enter
the passing plate.
・
The passing plate is not adjusted properly.
・
Too many screws are in the scooping
chamber.
・
Adjust the passing plate.
・
Reduce the quantity of screws to a proper
level.
9-6
No screw comes to the extraction site.
・
Screws are stopped while still on the rail.
・
Screws cannot be transferred smoothly
from the rail to the escaper.
・
Adjust the position of the holding plate.
・
Adjust the distance between the end of
the rail and the escaper or adjust the
height of the escaper.
9-7
The machine stops its operation suddenly.
・
The overload protective circuit was acti-
vated.
・
Too many screws are in the scooping
chamber.
・
A screw is caught in the clearance.
・
A screw, at the extraction site, could not
be extracted for an amount of time.
・
Turn the machine OFF and then ON
again.
・
Remove the cause of overload.
・
Remove screws to a proper level.
・
When the machine stops, even if the
screws are at a proper level, consult our
service section.
・
Remove the screw that is caught.
・
Remove the screw.