138
_____________________________________________________________________
8.2 Operation Sequence (Trigger mode setting)
______________________________________________________________
Setting the trigger timing
Setting the pre-trigger
Setting the Trigger mode
Setting the pre-trigger
Memory recorder
A waveform can be recorded before a
trigger event, as well as after the event.
Refer to section 8.4.
Setting the Trigger mode
REPEAT
AUTO
SINGLE
Trigger is registered only once. After
START
button was pressed,
product starts waveform recording when triggering occurs and
continues for preset recording length. Measurement then ends
automatically.
This determines whether the trigger is
accepted repeatedly after once
completing a measurement operation.
Refer to section 8.3.
Trigger is registered continuously. Product is in trigger standby
condition when trigger conditions are not met. Measurement ends
when
STOP
button is pressed.
Trigger is registered continuously. If trigger conditions are not met
within 1 second, waveform recording starts automatically and
continues for preset recording length. Measurement ends when
STOP
button is pressed
RMS recorder
Setting the trigger timing
Recorder
The interval between a trigger event
and waveform recording can be
specified.
Refer to section 8.5.
Start
Stop
Start&Stop
8.2 Operation Sequence (Trigger mode