UM DS-90xxHUHI-F8/N User Manual 041717NA
48
Figure 62, PTZ Panel, General
3.
Click the Call Pattern button to call it.
4.
Click the Stop Pattern button to stop calling it.
10.2.8.
Customizing Linear Scan Limit
Enable Linear Scan to trigger the scan in the horizontal direction in the predefined range.
NOTE:
NOTE:
NOTE:
NOTE:
This function is supported by certain models.
1.
Enter the PTZ Settings interface, Menu > Camera > PTZ.
Figure 63, PTZ Settings
2.
Use the directional button to wheel the camera to the location where you want to set the limit,
and click the Left Limit or Right Limit button to link the location to the corresponding limit.
NOTE:
NOTE:
NOTE:
NOTE:
The speed dome starts linear scan from the left limit to the right limit.
The left limit must be left of the right limit. The angle from the left limit
to the right limit must be no more than 180°.