![HIKVISION DS-2DB4223I-CX User Manual Download Page 79](http://html1.mh-extra.com/html/hikvision/ds-2db4223i-cx/ds-2db4223i-cx_user-manual_2132092079.webp)
© Hikvision
situations will lead to the video data error or loss.
This mode is used to correct the data error during transmission to ensure the image quality.
You can configure the error correction proportion within range of 0-100. When the proportion
is 0, the data error will be corrected by data retransmission. When the proportion is higher
than 0, the error data will be corrected via redundant data that is added to the stream and
data retransmission. The higher the value is, the more redundant date will be generated, the
more data error will be corrected, and the larger bandwidth is required. When the proportion
is 100, the redundant data will be as large as the original data, and the bandwidth is twice
required.
Note:
Be sure the bandwidth is sufficient in Error Correction mode.
5.
Save the settings.
Figure 6-20
Smooth Streaming
HTTP Listening
Note:
HTTP Listening is available to certain camera models.
Purpose:
Alarm information can be sent to destination IP or Host via HTTP protocol.
Steps:
1.
Input destination IP or host name, URL, and port number.
2.
Click Test to see if the service is available.
Note:
HTTP data transmission should be supported by the destination IP or Host.
3.
Save the settings.
Figure 6-21
HTTP Listening