ID5000 Series Smart Code Reader User Manual
79
Figure 8-63 Profinet
8.8.7 MELSEC
If
MELSEC
is selected as the
Communication Protocols
, you can enable
MELSEC Protocol Enable
and set
related parameters according to actual demands.
MELSEC Destination Address
It sets the IP address of the target PLC.
MELSEC Destination Port
It sets the port number of the target PLC.
MELSEC Data Base Address
It sets the first address of the data area.
MELSEC State Base Address
It sets the first address of the status area.
MELSEC Network Number
It sets the network No.
MELSEC PLC Number
It sets the PLC No.
MELSEC Module I/O Number
It sets the target module
’s I/O number.
MELSEC Module Station Number
It displays the module station number.
MELSEC Timeout
It sets the
waiting time before the returning of PLC’s response.