ID5000 Series Smart Code Reader User Manual
49
the specified string text, the trigger signal will be outputted.
Steps
1. Click
I/O Control Settings
→
Input
→
Trigger Mode
.
2. Select
On
as
Trigger Mode
.
3. Select
UDP Start
as
Trigger Source
.
4. Set
Trigger Delay
,
UDP Trigger Port
, and
UDP Start Trigger Text
according to actual demands.
Figure 8-28 Set and Execute UDP Trigger Mode
Set and Execute Serial Port Trigger Mode
Serial start specifies the serial port as the source for the trigger signal. When the serial port
receives the specified string text, the trigger signal will be outputted.
Steps
1. Click
I/O Control Settings
→
Input
→
Trigger Mode
.
2. Select
On
as
Trigger Mode
.
3. Select
Serial Start
as
Trigger Source
.
4. Set
Trigger Delay
,
Serial Baud Rate
,
Serial Data Bits
,
Serial Parity
,
Serial Stop Bits
, and
Serial
Start Trigger Text
according to actual demands.