![HikRobot ID5000 Series User Manual Download Page 57](http://html.mh-extra.com/html/hikrobot/id5000-series/id5000-series_user-manual_2131796057.webp)
ID5000 Series Smart Code Reader User Manual
48
3. Select
Counter 0
as
Trigger Source
.
4. Set
Trigger Delay
,
Count Number
,
Count Source
and
Line Out Trigger In Polarity
according to
actual demands.
Figure 8-26 Set and Execute Counter Trigger Mode
Set and Execute TCP Trigger Mode
TCP start specifies the TCP server as the source for the trigger signal. When the server receives the
specified string text, the trigger signal will be outputted.
Steps
1. Click
I/O Control Settings
→
Input
→
Trigger Mode
.
2. Select
On
as
Trigger Mode
.
3. Select
TCP Start
as
Trigger Source
.
4. Set
Trigger Delay
,
TCP Trigger Port
, and
TCP Start Trigger Text
according to actual demands.
Figure 8-27 Set and Execute TCP Trigger Mode
Set and Execute UDP Trigger Mode
UDP start specifies the UDP server as the source for the trigger signal. When the server receives